Air conditioner is type electric appliance, thus please do conduct reliable earthing
measure.
The yellow-green two-color wire in air conditioner is earthing wire and cannot be used
for other propose. It cannot be cut off and be fix it by screw, otherwise it would cause
electric shock.
The user power must offer the reliable earthing terminal. Please don't connect the
earthing wire with the following place:
Tap water pipe.  ②Gas pipe. Contamination pipe.
Other places that professional personnel consider them unreliable.
Note:
It should be reliably earthed, and it should be connected to the special earth device,
the installation work should be operated by the professional.
The air switch must have the functions of magnetic tripping and heat tripping, in order
to protect the short circuit and overloading.
.
The min. distance from the unit and combustive surface is 1.5m.
wrong connection may cause fire.
The power supply should be used the rated voltage and AC exclusive circuit,the power
cable diameter should be satisfied.
.
.
.
Voltage applying range: the normal running range is rated voltage 90%-110%.
Don't drag the power cable emphatically.
Safety Requirements For Electric Appliances
Notices for installation
6.
.
.
.
Make sure that the outdoor unit installation dimension should accord with installation
dimension diagram, convenient for maintenance, repair.
The height difference of connecting the tubing within 5m, the length of connecting the
tubing within 10m.
Select a place where it is out of reach for the children.
Select a place where will not block the passage and do not influence the city appearance.
4.
5.
The location should be able to withstand the full weight and vibration of the outdoor unit
and permit safe installation.
Select a dry place, but do not expose under the direct sunlight or strong wind.
2.
3.
Select a location where there should be sufficient ventilation.
Select a location where there should be no obstructions cover the inlet and outlet vent.
In case necessary, please consult your supply authority for system impedance information.
18K can be connected only to a supply with system impedance no more than 0.211 ohm.
In case necessary, please consult your supply authority for system impedance information.
24K can be connected only to a supply with system impedance no more than 0.466 ohm.
Make sure that the Live wire or Zero line as well as the earth wire in the family power
socket can not be wrong connected, there should be reliable and no short circuit in the
diagram.
Earthing requirements